Curtain wall and skylight testing
Ensure curtain wall and skylight products meet design requirementsWhat is curtain wall and skylight testing?
A curtain wall is a building façade in which the outer walls are non-structural. Typically designed with extruded aluminum members and infilled with glass, they are widely used for its aesthetically architectural appeal and they allow natural light into the building. As a protection against weathering, there is a need to consider its design requirements such as: thermal expansion and contraction; building sway and movement; water diversion; and thermal efficiency for cost-effective heating, cooling and lighting in the building.
Curtain wall testing standards
TÜV SÜD supports a complete range of major national and international curtain wall testing standards. These include –
- ASTM (E 283, 330, 331)
- AS/NZS 4284
- AAMA (501.1, 501.2, etc.)
- Singapore standards SS 654, SS 212, SS 268, SS 381 (Replaced by SS 654 : 2020)
- JIS (A1515, A1516, A1517)
- BS (5368, 6375)
- Field Air Infiltration Test (ASTM E 783)
- Field Water Test (ASTM E 1105 or AAMA 501.2)
Curtain wall testing procedure
TÜV SÜD’s testing procedure includes the following elements
- Air Infiltration Test – Rate of air leakage under specified pressure difference across the mock-up.
- Static Water Penetration Test – Checks interiors for water leakage and exterior face against a specified water rate.
- Dynamic Water Penetration Test – Applies dynamic pressure difference and specified water rate on the exterior face and checks interiors for water leakage.
- Cyclic Water Penetration Test – Applies cyclic pressure difference and water rate on the exterior face and checks for interior leakage.
- Structural Penetration Test – Checks for distress or failures and compliance with the standards.
- Proof Load Test – Uniform static pressure application and checks for fixing, stopping, or locking device failure.
- Lateral Movement Test – Movement due to inter-storey drift
- Vertical Movement Test – Movement due to live load on the floor slab.
TÜV SÜD facilities
- Sunshade load test
- Operate window sashes
- Acoustic Performance test
- 80 Displacement transducers
- Dynamic water penetration test
- Seismic and vertical movement test
- Positive test chamber for AS/NZS4284
- Seal degradation / BMU restraint load test
- Fully computerized data acquisition equipment
- Curtain Wall Chamber – size 14m (L) x 10m (D) x 16m (H)
- Fully automatic test procedure for static and cyclic
Get started with TÜV SÜD
Start your curtain wall and skylight testing journey with us.Benefits of curtain wall and skylight testing & inspection
- Protect your company from costly and image damaging scandals and recalls.
- Reduce your business risks by meeting regulatory requirements and standards.
- Increase quality and safety of your products and processes.
- Save time and costs as we provide you with a one-stop testing and certification service.
- Leverage on our global accreditations.
- Leverage on our state-of-the-art laboratories with comprehensive testing equipment and professional expertise.
- Increase customer confidence in your product when your product goes through independent testing.
- Shorten your time-to-market and increase market access when you meet regulatory requirements and standards.