Partition wall are non-load bearing walls that separate spaces in buildings. As well as spatial division, they can provide; privacy, acoustic and fire separation and flexibility of layout.
It may potentially be hazardous to the occupants if it is left unchecked. Without proper laboratory test for partition wall used in a building, it could affect the safety, comfort, and durability of the building materials.
Partition wall testing is important because manufacturers, developers and consultants can understand the characteristic and behaviour of the wall under vigorous testing in the lab before being build on-site. The test report on the partition wall performance such as strength performance, fire safety, water impermeability, thermal conductivity etc can help manufacturers and developers to ensure that the product is safe and fit to use
TÜV SÜD Malaysia and global laboratories are accredited by national and international standards that provides various testing for partition wall consist of dry wall, lightweight concrete wall, AAC blocks and autoclaved aerated lightweight concrete, clay brick, dry wall, partition board, lightweight concrete wall, AAC block, AAC wall panel, precast wall, IBS wall, non-load bearing wall, BS5234 Part 2, SS492, gypsum plasterboard, fibre cement wall, wall partition system, CIDB IBS, Jadual 6 Sistem innovative, prefabricated bathroom unit, PBU many more.
The test conducted in compliance with international standards and methods such as SS492:2001, BS5234 Part 2:1992, ISO 8302 or any other standards that are required by the local authority. With our accredited test report, manufacturers can meet with the local authority requirement such as CIDB, CIDB IBS, JKR etc
• Test according to SS492: 2001 and BS5234 Part 2:1992
• Acoustic Test - Sound transmission class (STC) ASTM E90 and ISO 10140-2 Airborne sound insulation
• Thermal conductivity – ISO 8302 & ASTM C518
• Air and Water penetration test – BS 4315: Part 2
• Heat Rain Test – BS EN 12467
• Fire test – BS 476: Part 4 Non-combustibility
• Fire test – BS476: Part 22
• Fire test – BS476: Part 6 & 7
• Reaction to fire test - EN13501-1
• Toxicity Emission test - BS EN 45545-2
• Density - BS EN 772-13
• Compressive Strength - BS EN 772-1
• Bending Strength - BS EN 772-6
• Water Vapour Permeability - BS EN ISO 12572
• Total Water Absorption – SS 271
• Gypsum plasterboards - BS EN 520
• Drying Shrinkage - BS EN 680
• Water Absorption due to capillary action BS EN 772-11
• Moisture movement - BS EN 772-14
• Structural performance test – ASTM E330
• Heat-rain performance test – BS EN 12467
• Guarded hot box - ISO 8990
• Mould resistance - ASTM D3273